SPDT vs DPDT is one question: does a second circuit have to move at the same time and stay electrically separate from the first? SPDT controls one changeover circuit, DPDT controls two, and everything else including terminal count, board area and unit price follows from that answer rather than driving it. Swiclick builds both across the MSS, MSK, SK and SS slide switch series and the PB series latching pushbuttons, and the single pole version is often the lower-cost part on the same body. Published DC switching ratings on those slide bodies run around 50V at 0.5A down to 30V at 0.2A depending on series. Pole count alone does not determine the electrical rating, so compare the exact part numbers, because ratings can vary by series, construction and certification. The topology decision starts with circuit behaviour, but the selected part number still needs its own rating and certification check.
Full detail on each configuration sits on the SPDT switch and DPDT switch pages. This page is only about which one to buy.
SPDT vs DPDT Comparison Table
| SPDT | DPDT | |
| Terminals | 3 | 6 |
| Circuits moved | 1 | 2, with no intentional connection between them |
| Board pads | 3 | 6 |
| Typical unit cost on the same body | Lower | Higher |
| Switches a signal and a separate return together | No | Yes |
| Selects between two isolated sources | No | Yes |
| Reverses polarity to a load | No | Yes |
| Reports position on a spare pole | No | Yes |
Decision rule: choose DPDT only when a second circuit must move at the same time and stay electrically separate. Otherwise SPDT is sufficient and cheaper.
When the Second Pole Pays for Itself
Four situations justify the extra three terminals.
The return is not shared. If your two circuits do not share a ground, opening only the live side leaves a path through the return. Both sides have to break. This is the most common legitimate reason.
You are selecting between two isolated sources. Two supplies with separate returns, one selector. Specify non-shorting here, because a make-before-break part will connect the two sources during every transition.
You need the state reported separately. One pole carries the working circuit, the other drives a controller input. Reading position from a dedicated pole is more reliable than inferring it from the load side, and it costs nothing extra once you have the second pole.
You are reversing polarity. Crossing the throws is the standard way to reverse a small DC load. Check the published DC rating before connecting anything directly.
When One Pole Is Already Too Many
The opposite case is more common than most BOMs suggest.
If the return is board ground, one pole is enough. If the switch only selects a mode and a controller reads it, one pole is enough. If the switch only turns something on and off, you may not even need a changeover, and the SPST and SPDT decision is worth running first.
There is a habit in some design teams of specifying DPDT as a default and wiring only one pole. On a single board that is a rounding error. Over a production run it is real money and three extra pads in a layout that is usually already tight.
Keeping a spare pole for a planned revision is a defensible choice. Write it into the schematic notes so it reads as a decision rather than an oversight.
What Changes on the Board
Three practical differences show up at layout, and none of them are about the circuit.
Footprint. Six terminals in two rows is a wider part than three in one row on most bodies. Check the actual footprint drawing rather than assuming the body grows only slightly.
Pad count and routing. Three extra pads in a dense area can force a via or a layer change that costs more than the switch.
Assembly orientation. A six-terminal body is often symmetrical, so a mirrored placement still fits and still works while reading backwards. Mark pin 1 and the on direction on the silkscreen.
The DPDT slide switch page covers pinouts and mounting styles for the slide format specifically.
Certification Does Not Change With Pole Count
One thing that does not vary is the standard the part is evaluated against.
Requirements and rating rules for mechanical switches of this class sit in IEC 61058-1-1 whatever the pole count. Approval is granted against a specific model, rating and construction, so moving from a single pole part to a double pole part in the same series still means a new certification check.
If your compliance file names a part number, changing pole count changes the part number. Verify the new model against the applicable certification scheme before the file is updated.
FAQ
The number of independent circuits moved. SPDT moves one, DPDT moves two with no intentional connection between them, and both move between two destinations.
Electrically it behaves like two, driven by one mechanism. Contact timing between the two poles is not perfectly matched, so they are not two fully independent switches.
Usually yes. Wire one pole and leave the other open, keeping its pads on the board. Check that the ratings and footprint suit. The reverse substitution is not possible.
Usually DPDT on the same body, but not always by much. On some series the double pole version is the higher-volume part, so ask for both prices rather than assuming.
For a mechanical polarity reversal, yes. Check the published DC rating first, because small PCB switches are commonly rated in tenths of an amp.
It changes the part number, and approval is granted per model and rating. Treat it as a new verification rather than assuming the series is covered.