Home Appliance Switches for OEM and EMS Projects
A refrigerator door closes, a washer lid latches, a cooktop key is pressed, and the appliance controller acts on the state of one small switch. When that switch is poorly matched, the problem seldom shows on the bench. It shows up after plastic tolerances stack up in the assembled cabinet, after the first 100,000 door openings, or the first time a lamp driver’s inrush current passes through contacts selected for a resistive load. By then the bracket, PCB and harness are usually frozen.
This page is written for appliance OEMs, ODMs and EMS providers sourcing home appliance switches, mainly micro switches and tact switches, for production. It maps common appliance functions to real Swiclick part numbers, including a 1,000,000-cycle option for high-frequency door and mechanism duty, and lists the information that produces a useful recommendation in the first reply.
Have an incumbent part number, a mechanism drawing or a new appliance BOM? Request engineering samples and a model review. Four lines in the message field are enough to start:
- Application: door or lid status, mechanism position, control panel key, or load switching.
- Incumbent part: brand and full part number with suffix, if one exists.
- Electrical duty: AC or DC, voltage, current and load type.
- Volume and life: annual quantity, actuations per day and design life in years.
Drawings, datasheets and BOM extracts go to sales001@swiclick.com with the project name in the subject line. An NDA is available on request.
- Engineering samples: 1 to 50 pieces free of charge for qualifying OEM, ODM and EMS projects using standard models, shipped within four working days. Custom or modified parts follow a separate feasibility and sample schedule.
- Standard production lead time: 7 to 15 working days.
- Quality systems: ISO 9001 and IATF 16949.
- Range: G-series micro switches with selected AC ratings up to 16 A at 125/250 VAC, with selected plunger and long-lever models rated for 1,000,000 mechanical cycles, and KAN tact switches with 100, 160 and 260 gf force options, including IP67 versions.
Match the switch to the appliance function
Two switches with the same body can do very different jobs. Start from the function, then choose the package.
| Appliance function | What the switch must do | Candidate type | What decides the exact model |
|---|---|---|---|
| Refrigerator or freezer door, lamp and fan control | Change state on every opening for the whole product life; often closes a lamp or fan circuit when the door opens | Plunger or lever micro switch, using the NC contact of an SPDT part where the circuit must close with the door open. High-frequency duty: check mechanical life, electrical life at the actual load and the travel window before anything else. | Openings per day multiplied by design life, lamp or fan load and its inrush, condensation, operating and release positions at worst-case gasket compression |
| Washer lid, dryer door or dishwasher door status (non-safety signal) | Report open or closed to the controller | Micro switch with plunger or lever. Same three checks as above where the door is opened many times a day. | Logic voltage and current, minimum switching load, humidity and detergent exposure, travel window |
| Microwave door interlock and other protective functions | Act as one element of a certified safety system with a defined switching sequence | Approved door-switch assembly or switches specified by the appliance safety design | Appliance standard, sequence timing, approval of each switch, system-level testing |
| Mechanism position (tray, latch, dispenser, blender jar, small-appliance lid) | Detect a moving part at a defined position | G15 miniature micro switch (PCB) or G20 basic switch (chassis), including a long-lever option for mechanisms needing a low-force, more distant actuation point | Approach direction, mounting datum, overtravel, vibration, expected cycles |
| Direct load switching (heater, motor, pump, lamp) | Make and break a mains load | G20 16 A basic switch, or a G15 6 A or 10 A part where the load allows | Resistive, inductive, lamp or LED-driver load; horsepower rating; electrical life at the actual load; ambient temperature at the switch |
| Control panel keys | Momentary input to a microcontroller | PCB tact switch; sealed IP67 tact switch where liquid or condensation can reach the PCB | Footprint, force and travel through the panel stack-up, bounce, soldering process, sealing |
| Second source for an existing BOM | Match the incumbent with the least redesign | Candidate chosen from the exact incumbent specification | Full MPN with suffix, drawing, pin map, approvals, qualification plan |
Microwave ovens show why the safety boundary matters. Their doors typically operate primary and secondary interlock switches plus a monitor switch that deliberately blows the line fuse if an interlock fails to open in the correct sequence. A general-purpose micro switch, even one with component recognition, does not make that system safe or certify the appliance on its own. The appliance designer decides which switches, approvals and switching sequence the system needs.
For control panel keys, Swiclick’s published Midea microwave oven project describes KAN0651, KAN0656, KAN1211 and KAN1216 tact switches used on the control panels of Midea smart microwave ovens. That project covers panel inputs only.
Swiclick part numbers for appliance engineering review
The seven configurations below are published Swiclick models and are starting points for engineering review. Use the linked datasheets and controlled drawings for final dimensional and electrical checks. None is a universal appliance door switch, a confirmed drop-in replacement or an IP-rated model.
| Model | Actuator and installation | Published rating and cycle life | Key OEM checks |
|---|---|---|---|
| G20-16CM-150-08 | SPDT pin plunger; chassis mount; 29 × 10.1 × 15.9 mm | 16 A resistive / 10 A inductive at 125/250 VAC; 1,000,000 mechanical; 10,000 electrical at 16 A, 250 VAC | OF 150 ± 50 gf; OP 17.5 ± 0.5 mm; PT 2.0 mm max. Short travel. -25 to +125 °C; cURus / CQC. |
| G20-16EM12-30-37 | SPDT 52 mm long lever; chassis mount; 29 × 10.1 × 15.9 mm body | 16 A resistive / 10 A inductive at 125/250 VAC; 1,000,000 mechanical; 10,000 electrical at 16 A, 250 VAC | OF 30 ± 10 gf; OP 20 ± 1.5 mm; PT 5.0 mm max. Check strike geometry, overtravel and vibration. -25 to +125 °C; cURus / CQC. |
| G15-06SM01-40-01 | SPDT straight leaf-spring lever; PCB solder mount; 19.8 × 6.5 × 10 mm | 6 A resistive / 3 A inductive at 125/250 VAC; 100,000 mechanical; 10,000 electrical at 6 A, 250 VAC | OF 40 ± 20 gf; OP 12 ± 0.8 mm; PT 3.6 mm max. -25 to +125 °C; CQC listed. |
| G15-10SM-150-22 | SPDT pin plunger; PCB solder mount; 19.8 × 6.6 × 10 mm | 10 A resistive / 5 A inductive at 125/250 VAC; 100,000 mechanical; 10,000 electrical at 10 A, 250 VAC | OF 150 ± 50 gf; OP 11.4 ± 0.4 mm; PT 1.1 mm max. -25 to +125 °C; CQC listed. See 5E4 note. |
| G20-16EN03-70-07 | SPST-NO straight lever; chassis mount, quick-connect | 16 A resistive / 10 A inductive at 125/250 VAC; 100,000 mechanical; 10,000 electrical at 16 A, 250 VAC | OF 70 ± 20 gf; OP 22.2 ± 1.5 mm; PT 5.0 mm max. No NC terminal. -25 to +85 °C; cURus / CQC. |
| G20-16EM-150-22 | SPDT pin plunger; chassis mount, 3 terminals | 16 A resistive / 10 A inductive at 125/250 VAC; 100,000 mechanical; 10,000 electrical at 16 A, 250 VAC | OF 150 ± 50 gf; OP 17.5 ± 0.5 mm; PT 2.0 mm max. -25 to +85 °C; cURus / CQC. |
| KAN0652-0501C0101-42 | SPST-NO momentary tact switch; 2-pin through-hole; 6 × 6 × 5 mm | 12 VDC / 50 mA max; 100,000 operating cycles | OF 260 ± 50 gf; travel 0.25 ± 0.1 mm; -30 to +80 °C. No product approval listed. |
OF = operating force, OP = operating position, PT = pretravel.
If none of these models matches your mounting, actuation, life or approval requirements, send your drawing or incumbent part number for an engineering review. The seven parts above are a cross-section of the range, not the whole catalog, and controlled modifications are assessed per project.
What the table means for an appliance design:
- High-cycle candidates still require validation. G20-16CM-150-08 (plunger) and G20-16EM12-30-37 (52 mm lever) each list 1,000,000 mechanical cycles. This provides a useful starting margin for frequent door actuation, subject to actual load, geometry, environment and endurance testing. Both list only 10,000 electrical cycles at the full 16 A, 250 VAC rating. The long lever offers a different actuation geometry, but its 5.0 mm maximum pretravel does not guarantee adequate overtravel or fit in a particular door mechanism.
- The temperature limit differs by model. Both G15 parts, G20-16CM-150-08 and G20-16EM12-30-37 are rated to +125 °C; G20-16EN03-70-07 and G20-16EM-150-22 stop at +85 °C. Near oven cavities, heating elements or dryer air paths, measure the air temperature at the switch location before choosing.
- The ratings are AC ratings. No DC rating is listed for the six G-series parts, so DC capability must not be inferred from the AC values.
- The contact form decides the wiring. G20-16EN03-70-07 is normally open only. For a circuit that must close when the door opens, such as a cabinet lamp, use the NC terminal of an SPDT part.
- Tact switches are signal devices. KAN0652 is rated 12 VDC 50 mA maximum and 1 VDC 10 µA minimum, so it must never switch mains or motor loads.
- Approvals are model-specific. For North American and European appliance programs, confirm the component approval and the certification scope of the exact model before requesting production qualification samples. The two G15 parts list CQC only; the four G20 parts list cURus and CQC; KAN0652 lists none. Swiclick holds UL, ENEC and TÜV Rheinland approvals for selected products, and the file covering a given part number and market has to be confirmed for that model.
For more PCB-mount configurations, see the G15 micro switch series. For other actuators and current ratings, use the micro switch range. For control panels exposed to liquid or condensation, review the IP67 waterproof tact switch options and the wider tact switch range.
How to read appliance switch ratings
Switches tested to IEC 61058-1, the switch standard for appliances, carry a compact rating marking. The G15-10SM-150-22 page lists 10 A resistive and 5 A inductive at 125/250 VAC, 1/2 HP, and the marking 25T125 µ 5E4.
| Marking element | Meaning | Why it matters |
|---|---|---|
| Current values such as 10 A / 5 A | Resistive load current and inductive or motor load current. IEC-style markings put the motor current in brackets, for example 16(4) A. | Use the value that matches your load. Lamp loads and LED drivers need a separate inrush check. |
| 125/250 VAC | Rated AC voltages | DC switching is outside this rating. |
| 25T125 | Ambient limits of the switch: -25 °C to +125 °C. A marking of T125 alone means a lower limit of 0 °C. | Check the lower limit for freezers and the upper limit near heat sources. |
| µ | Micro-disconnection. Switch makers mark switches that are not suitable for full disconnection with the µ symbol. | A µ switch cannot serve as the disconnecting device where the appliance standard requires full disconnection. |
| 5E4 | Marking convention denotes 5 × 10⁴ operating cycles. The certification basis and endurance conditions for this exact model have not yet been confirmed. | Do not use the marking as proof of 50,000 cycles at the product page’s 10 A, 250 VAC condition without the relevant records. |
| 1/2 HP, 1 HP | North American motor ratings | Relevant when the switch drives a motor directly. |
Caution on 5E4 and listed electrical life. The published specifications for G15-10SM-150-22 list both a 5E4 marking and an electrical life of 10,000 cycles at 10 A, 250 VAC. The relationship between these figures and their respective test conditions has not yet been confirmed. Request the relevant certification and endurance test records before using either figure to establish the required service life.
Certificate editions matter too. IEC 61058-1 Edition 5.0 was published in July 2026, while many valid certificates still cite the 2016 edition with IEC 61058-1-1. Ask which edition each certificate references and confirm with your certification body which one it accepts for your launch date. For switching mechanisms and electrical life definitions, see the snap action switch technical guide.
Engineering checks that decide qualification
1. Actuation travel at tolerance extremes
A switch that clicks on the bench can fail in the assembled appliance, because the travel delivered to the actuator changes once door seals compress, mouldings vary, brackets shift and hinges wear.
Work in one coordinate system. Swiclick product pages give the operating position (OP) as a height above the mounting datum, with pretravel (PT) measured from the free position. Express the mechanism the same way: the height of the moving strike above the same datum, with the door closed and with the door open, at both tolerance extremes. Then ask for the model drawing to obtain the values the web tables do not show: overtravel (OT) or total travel position (TTP), and movement differential (MD), which sets the release position (RP).
- Operate: the highest closed-door strike height must sit below the lowest OP in the tolerance band, with margin.
- Protect: the lowest strike height must stay above TTP, including shock and slam conditions.
- Release: the open-door strike must clear the highest release position, which is OP plus MD at the top of their tolerances.
- Target band: Omron recommends a pushed position between 60% and 90% of the distance from OP to TTP. An operating body that stops close to OP or RP can cause contact chatter.
Worked example. The OP value comes from the G15-10SM-150-22 product page. The TTP and the mechanism figures are hypothetical and only illustrate the method.
| Item | Value | Result |
|---|---|---|
| Switch OP (product page) | 11.4 ± 0.4 mm, so 11.0 to 11.8 mm | |
| Switch TTP (hypothetical; take it from the real drawing) | 9.8 mm | |
| Closed-door strike height (hypothetical tolerance stack) | 10.2 ± 0.5 mm, so 9.7 to 10.7 mm | |
| Operate check | 10.7 mm is below 11.0 mm | Pass, 0.3 mm margin |
| Protection check | 9.7 mm is below 9.8 mm | Fail, 0.1 mm beyond TTP |
| 60 to 90% target band (nominal OP to TTP) | 10.44 to 9.96 mm, a band 0.48 mm wide | The 1.0 mm strike range does not fit |
The switch operates, yet a ±0.5 mm stack is too wide for a short-travel plunger. The options are a tighter stack, a mechanical stop, or a lever actuator with longer travel, such as G15-06SM01-40-01 (pretravel up to 3.6 mm at 40 ± 20 gf), followed by the same check against that model’s drawing.
2. Cycle life against real use
Multiply the actuations per day by the design life of the appliance, then compare the result with the listed life of the exact model.
The figures below illustrate the method using published field studies. They are not a usage specification: actual frequency varies by region, household and product, so a formal project should use the operating cycles and reliability target your own programme defines.
| Use case | Usage basis | Cycles over 12 years | Compare with |
|---|---|---|---|
| Fresh-food door, field average | 32.5 openings per day (NIST field study) | About 142,000 | 100,000 cycles for several models; 1,000,000 for G20-16CM-150-08 and G20-16EM12-30-37 |
| Fresh-food door, heavy use | 48 openings per day (New Jersey study cited by ACEEE) | About 210,000 | Same as above |
| Freezer door | 7 openings per day (NIST field study) | About 31,000 | Within 100,000 cycles |
| Cooktop or oven key (illustrative) | 20 presses per day (assumption) | About 88,000 | 100,000 cycles for KAN0652; KAN models range from 100,000 to 1,000,000 cycles |
Three points follow from this table.
- The 12-year illustrative count exceeds the 100,000-cycle rating of several models. G20-16CM-150-08 and G20-16EM12-30-37 list 1,000,000 mechanical cycles, giving potential margin that still needs to be validated against the real mechanism and load.
- Compliance minimums and field life are separate numbers. According to Intertek’s summary of the UL 60335-2-24 transition, the refrigerator standard requires door switches rated for 50,000 operating cycles. Meeting that is not the same as surviving field use.
- When the switch carries a load as well, the electrical life at that load usually governs, and all six G-series models above list 10,000 electrical cycles at their published full-load test condition.
If your duty budget exceeds the life of a candidate, state the requirement in the enquiry so a different configuration can be assessed. Send the actuations per day, the design life and the actual load, and Swiclick can confirm whether a listed model, another configuration or a controlled modification covers it.
3. Electrical duty, inrush and low-level signals
State whether the switch only reports a logic input or directly carries a load. For a powered circuit, give the voltage, steady-state current, inrush current, load type, switching rate and any suppression network.
Inrush. Omron’s basic switch precautions classify a lamp load as having an inrush current about ten times the steady-state current and a motor load about six times. LED lamp drivers with input capacitors can draw short, high current peaks that weld undersized contacts. Measure the inrush of the actual driver or motor, and compare motor loads with the horsepower rating: 1/2 HP for the G15 parts above, 1 HP for the G20 parts.
Low-level inputs. When a silver-contact switch rated 10 A or 16 A only reports a door state to a microcontroller, the current can be too small to keep the contact surfaces clean, and contact resistance can drift. In humid cabinets, silver migration can also create leakage paths. Ask for the minimum switching load of the exact model, consider a higher wetting current through a lower-value pull-up resistor, ask whether a gold-plated contact option exists for that family, and run damp-heat testing in the real circuit. The switch contact resistance and failure guide covers measurement methods.
Debounce. KAN0652 lists a bounce time of 10 ms or less at make and at break. Set the firmware debounce window longer than the published bounce, for example 15 to 20 ms, and verify it on the real board with the real key cap and overlay.
4. Terminals, PCB and assembly
An SPDT switch and an SPST-NO switch with a similar body are different circuits. Record the state mapping on the drawing for every switch:
| Door state | Switch state | SPDT (COM, NO, NC) | SPST-NO |
|---|---|---|---|
| Closed, actuator pressed | Operated | COM-NO closed, COM-NC open | Closed |
| Open, actuator released | Released | COM-NC closed, COM-NO open | Open |
| Connector unplugged | Not connected | Open circuit at the connector. The state the controller reports depends on input biasing, wiring and fault detection design. | Open circuit, same qualification |
“Normally open” refers to the unactuated switch, and which door position leaves the actuator free depends on the design. Writing the mapping down prevents inverted logic and makes the disconnected case a deliberate design decision rather than an assumption.
- PCB parts: match pin pitch, hole diameter, board thickness and terminal orientation. The G15 parts above use three PCB solder pins; KAN0652 uses a 2-pin DIP layout. Through-hole DIP and SMT tact switches cannot be swapped without reviewing the footprint and the soldering process.
- Soldering and cleaning: unsealed switches can draw flux or cleaning fluid into the contact area during wave or selective soldering. Specify the flux type and process, or choose a sealed part, and mask switches during conformal coating.
- Quick-connect tabs: for G20-16EN03-70-07, confirm tab width and thickness against the harness receptacle and check the pull-off force on the assembled harness.
- Control panel stack-up: the key cap, overlay, spacer and PCB flatness change the force and travel the user feels. Qualify force uniformity across every key on the assembled panel, because a bare PCB hides stack-up effects.
- EMS documents: request the 2D drawing, pin map and packaging data with the quote. The G-series parts above ship in bags and KAN0652 ships 2,500 pieces per box, so confirm packaging if parts feed automated insertion.
5. Heat, moisture and contamination
- Heat: measure the air temperature at the switch during the worst-case program, such as a self-clean cycle, high-heat drying or a cooktop at full power, and compare it with the model limit (+125 °C for the G15 parts, G20-16CM-150-08 and G20-16EM12-30-37; +85 °C for the other two G20 parts; +80 °C for KAN0652).
- Cold: in freezer compartments, check the lower limit: -25 °C for the G-series parts above and -30 °C for KAN0652.
- Moisture: refrigerator cabinets collect condensation after door openings, dishwashers vent steam and laundry rooms stay humid. None of the seven parts above lists an IP rating, so do not describe them as waterproof. Protect micro switches by location or shielding, use sealed tact switches where liquid can reach the panel PCB, or evaluate a sealed alternative.
- Grease and detergent: near cooking zones, grease can hold a plunger down or contaminate contacts. Keep the actuator path clear of splash, and include contamination in the test plan.
6. Approvals and the safety-function boundary
First classify the function: status indication, a non-safety process interlock, or a protective function. Each needs different evidence.
- Appliance level: IEC 60335-1 with the relevant Part 2, for example IEC 60335-2-24 for refrigerators, IEC 60335-2-25 for microwave ovens, IEC 60335-2-7 for washing machines and IEC 60335-2-5 for dishwashers, plus national versions such as UL 60335 in North America.
- Switch level: IEC 61058-1 with IEC 61058-1-1 for mechanical switches, and UL 61058-1 in North America. Check the certificate scope for rating, temperature code, cycle declaration and the exact model.
- Quality systems: ISO 9001 and IATF 16949 describe how production is managed. They do not replace a product approval.
- Safety functions: where a switch forms part of a protective system, the switches, their sequence and the complete appliance are approved together. A catalog basic switch enters such a design only where the system designer specifies it.
Sample qualification before production release
A useful sample trial evaluates the identified part number in the real appliance assembly and records whether the same configuration can be approved for repeat production.
- Freeze the candidate. Record the full MPN, contact form, actuator, terminals, drawing revision and certificate scope.
- Check fit and travel. Install the switch on the real bracket or PCB and verify operate, release and protection at tolerance extremes, before and after representative cycling.
- Test electrically. Confirm state mapping, contact resistance and bounce on the real control board. Where the switch carries a load, test at the actual load and inrush with an agreed safe procedure.
- Test the environment. Apply the project’s temperature, humidity, contamination, vibration and cycling requirements. Treat these as project tests, separate from catalog claims.
- Record measurements. Document operating position, force, contact resistance and other critical characteristics against defined limits with traceable sample IDs.
- Approve the production configuration. Agree incoming inspection, retained samples, traceability, change notification and the conditions that trigger requalification.
| Approval stage | What the OEM receives | Typical release decision |
|---|---|---|
| Candidate screening | Datasheet, model drawing, ratings and certificate scope | Worth sampling, with gaps identified |
| Engineering samples | Identified samples and an agreed test plan | Fit, function and application validation in progress |
| Production qualification | Measured results against limits, configuration record, quality plan | Approved for the defined BOM and application |
If you are replacing an existing brand, the switch second source solutions page describes the comparison workflow, and the Omron cross reference page covers common Omron part numbers. Every candidate remains subject to verification in the final application.
Send your appliance switch RFQ
You can start from an incumbent part number or from a new mechanism and circuit. The first column below is enough for an actionable reply; the second becomes important during sample approval.
| RFQ field | Supply initially | Add during qualification |
|---|---|---|
| Appliance function | Door or lid status, mechanism position, control panel key or load switching | Block diagram and the defined safe state, if relevant |
| Existing switch | Brand and full part number with all suffixes, or a photo if no number is visible | Datasheet, drawing and the reason for a second source |
| Electrical duty | AC or DC, voltage, current, load type (resistive, motor, lamp or LED driver, logic input) | Inrush, switching rate, life-test conditions |
| Mechanical interface | Installation space, drawing or photos | Strike height range, OF, OP, OT, tolerance stack, mounting details |
| PCB or harness | PCB or chassis mounting, terminal type, contact form | Footprint, soldering process, receptacle type, packaging |
| Environment and market | Temperature at the switch, moisture or grease exposure, target markets | Required approvals and the appliance test plan |
| Volumes and life | Annual volume, actuations per day, design life in years | Sample schedule and PPAP, FAI or other qualification requirements |
What you receive back: one or more candidate part numbers with datasheet and drawing, or a clear statement that no standard Swiclick part fits; a list of open items, such as overtravel data, approval scope or life at your load; and the sample quantity and shipping date for qualifying standard models.
For a fast review, submit the four starting inputs above through the contact form, or email your drawing and full part number to sales001@swiclick.com. Include your company and project reference so the candidate configuration can be identified correctly.
Frequently asked questions
Which switch should an OEM use for an appliance door or lid?
Start from the strike geometry, the circuit state you need with the door open and closed, the number of openings over the product life, and the approvals required. A plunger or lever micro switch can suit status sensing when its operating and release positions work across the appliance tolerances and its life covers the duty. Protective interlocks, such as microwave door systems, need component and system approval as a set.
Is there a micro switch rated for high-frequency appliance doors?
Two published G20 candidates list 1,000,000 mechanical cycles: G20-16CM-150-08 uses a plunger, while G20-16EM12-30-37 uses a 52 mm lever with 30 ± 10 gf operating force and 5.0 mm maximum pretravel. Both list only 10,000 electrical cycles at the full 16 A, 250 VAC rating. Actual door life, actuation and approval suitability must be verified in the appliance.
What does 25T125 µ 5E4 mean on a micro switch?
25T125 gives the ambient temperature limits of the switch, -25 °C to +125 °C. The µ symbol marks micro-disconnection, meaning the switch is not intended for full disconnection of the supply. 5E4 is a marking convention for 50,000 cycles, but the relevant certified test conditions have not been confirmed for this part. The product page separately lists 10,000 electrical cycles at 10 A, 250 VAC. Obtain the test records before selecting a life figure for your load.
Is a 16 A micro switch suitable for a low-voltage controller input?
A high AC rating does not guarantee reliable switching at microampere or low milliampere levels. Check the minimum switching load of the exact model and qualify the input in the real circuit. For a manually pressed key on a PCB, a tact switch rated for signal loads is usually the better candidate.
How many free samples can we request, and how quickly do they ship?
For qualifying OEM, ODM and EMS projects using standard models, Swiclick provides 1 to 50 pieces free of charge, shipped within four working days. Custom or modified configurations follow a separate feasibility and sample schedule. Link each sample batch to the drawing revision that will be used for purchasing.
Are these switches waterproof?
The G15, G20 and KAN0652 parts listed on this page carry no IP rating. Selected KAN tact switches are available with IP67 sealing; confirm the protection level of the exact model and validate it in the assembled appliance.
Which approvals do these part numbers carry?
Approvals depend on the exact model. On their product pages, the two G15 parts list CQC, the four G20 parts list cURus and CQC, and KAN0652 lists none. Request the current certificate for your target market and rating. The appliance manufacturer remains responsible for the compliance of the finished appliance.
Can we buy a single replacement switch for an appliance repair?
Swiclick supplies OEM, ODM and EMS production programmes. For a replacement part for an appliance already in service, the appliance brand’s authorised parts channel is the right source, because the replacement must match the originally approved part.