Six terminals, two of them commons, and a slider that moves both circuits at once. A DPDT slide switch has two poles and two throws, so one actuator moves two electrically independent circuits between two positions. Swiclick builds this configuration across the MSS, MSK, SK and SS series in surface mount and through hole, from small PCB bodies up to panel-mount sizes. Published DC switching ratings on this class run around 50V at 0.5A, 50V at 0.3A or 30V at 0.2A depending on series, and initial contact resistance is commonly specified at 100mΩ or below. Actuation is horizontal slide, side slide or right angle. Miniature PCB slide switches do not give the operator-independent contact transfer that a true snap-action basic switch does, which is what caps their switching ratings. Contact form, terminal layout and detent behaviour all vary by series.
What the Six Pins Do
Line the terminals up in two rows of three and the logic becomes readable.
Each row is one pole. On many conventional two-row six-pin bodies the middle terminal in each row is that pole’s common and the outer two are the throws. That layout is common but it is not a law. Terminal numbering, internal connection and footprint orientation vary between manufacturers and between series.
The connected throw also cannot safely be inferred from which way the slider is pushed. Some designs move the internal wiper opposite to the visible actuator. Verify both the common and the direction from the contact diagram in the specific datasheet, or with a continuity check on the first board.
Marking pin 1 and the on direction on the silkscreen costs nothing and prevents a mirrored assembly that fits, works electrically and reads backwards to the user.
Two Poles or One
Most designs that specify DPDT need only one pole. It is worth checking before the BOM freezes, because an SPDT slide switch in the same body style costs less and takes fewer pads.
The switch pole and throw notation is the same across every switch family, so DPDT means the same thing on a toggle, a slide and a rotary. Use DPDT when you genuinely have two circuits to move together: switching both a signal and its return, selecting between two supplies while flagging the choice to a controller, or reversing a small DC motor by crossing two lines. Use SPDT when you are moving one line and the return is common.
The two poles are galvanically isolated for normal low-frequency switching. For high-speed or precision differential signals, contact skew between the poles, inter-pole capacitance and impedance discontinuity have to be evaluated rather than assumed away. Do not treat the two poles as an ideal matched pair.
Throws, Positions and Detents
Poles and throws describe the circuit. Positions and detents describe the feel, and they are specified separately.
A two-position DPDT has two detents. A three-position variant, usually written DP3T or 2P3T, adds a center detent. Whether that center position is open or connected is a separate question and a common source of returns. A three position slide switch can be on-off-on or on-on-on, and the part numbers look nearly identical.
The specification that gets skipped most often is shorting versus non-shorting. A shorting switch briefly connects both throws during the transition, sometimes called make-before-break. A non-shorting switch opens the first contact before closing the second. If you are switching between two power supplies, a shorting switch will briefly connect them together during every transition.
Swiclick lists at least one part explicitly marked non-shorting in the DP3T range. For any multi-position application, name the behaviour you need in the RFQ rather than accepting the default.
Ratings and Why They Look Low
Ratings on this class sit far below what people expect from a switch of that physical size.
Contact transfer here depends much more on actuator movement than it does in a snap-action switch. A slow push produces a long, low-pressure wipe and can sustain an arc if current is flowing. Many miniature slide switches are therefore best used for signal-level or low-power switching. Requirements and rating rules for mechanical switches of this type sit in IEC 61058-1-1.
Do not treat the whole category as dry-circuit only, though. Dry circuit is a defined low-voltage, low-current, essentially arc-free condition, and Swiclick lists parts with published DC switching ratings well above it. Use the exact tested switching rating for the part you have chosen.
Some datasheets also publish a higher non-switching or carry-current limit. Where that figure exists it is useful. Where it does not, do not infer it from the switching rating.
The practical rule is to switch a slide switch cold wherever possible: put it on the logic side of a MOSFET or a relay rather than in the power path.
Package and Mounting
Four mounting styles cover the range.
Through hole, horizontal actuation. The default. Slider moves parallel to the board.
Surface mount. For designs that cannot afford a through hole in a dense board. An SMT miniature 6 pin DPDT part in the MSS series is the typical choice. Confirm the actuator material against the reflow profile you intend to run.
Right angle. Slider moves perpendicular to the board so it can protrude through a case wall.
Side slide. Actuator on the side face of the body, used where the case opening sits beside rather than above the board.
Actuator height and knob shape usually decide the part number in a real enclosure, not the electrical spec. Fix the case opening geometry first.
Specifying One
- Poles and throws, and whether a center position is needed
- Shorting or non-shorting, stated explicitly
- Mounting style and actuator direction
- Actuator height above board and knob shape
- Switched voltage, current and whether it is DC
- Contact resistance requirement at end of life if the circuit is sensitive
- Annual volume
Swiclick quotes standard parts from the slide switch range with a 500-piece minimum order quantity. Custom knob geometry is a tooling item, and reusing an existing body while changing only the actuator is the cheaper route.
FAQ
Double pole, double throw. Two independent circuits move between two positions with one actuator. The package normally has six terminals.
On many conventional two-row six-pin bodies it is the middle terminal in each row. Always verify against the continuity diagram and terminal numbering in the specific datasheet.
Not reliably. Some designs move the internal wiper opposite to the actuator. Check the contact diagram or run a continuity test.
Electrically yes, by crossing two lines. Check the published DC rating first. Parts in this class are commonly rated in tenths of an amp, which limits it to very small motors.
A shorting switch connects both throws briefly during transition. A non-shorting switch breaks before it makes. Switching between two supplies needs non-shorting.